DEVELOPMENT OF LARGE-VOLUME, HIGH-RESOLUTION TRACKING DETECTORS BASEDON CAPILLARIES FILLED WITH LIQUID SCINTILLATOR
Autore:
BUONTEMPO S; FABRE JP; FRENKEL A; GALEAZZI F; GOLOVKIN S; GREGOIRE G; HARRISON K; HOEPFNER K; KONIJN J; KOZARENKO E; KRESLO I; KUSHNIRENKO A; MARTELLOTTI G; MAZZONI MA; MEDVEDKOV A; MICHEL L; MOMMAERT C; MONDARDINI MR; PANMAN J; PENSO G; PETUKHOV Y; SIEGMUND WP; STRACK R; TYUKOV V; VASILCHENKO V; VILAIN P; WILQUET G; WINTER K; WONG H; ZYMIN K;
Indirizzi:
HUMBOLDT UNIV BERLIN BERLIN GERMANY HUMBOLDT UNIV BERLIN BERLIN GERMANY IST NAZL FIS NUCL I-80125 NAPLES ITALY CERN CH-1211 GENEVA SWITZERLAND UNIV ROMA LA SAPIENZA ROME ITALY IST NAZL FIS NUCL ROME ITALY IHEP PROTVINO RUSSIA UNIV CATHOLIQUE LOUVAIN B-1348 LOUVAIN BELGIUM UNIV LONDON IMPERIAL COLL SCI TECHNOL & MED LONDON ENGLAND NIKHEF AMSTERDAM NETHERLANDS JOINT INST NUCL RES DUBNA DUBNA RUSSIA SCHOTT FIBER OPT INC SOUTHBRIDGE MA 01550 FREE UNIV BRUSSELS,IIHE BRUSSELS BELGIUM
Titolo Testata:
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment
fascicolo: 1-2, volume: 360, anno: 1995,
pagine: 7 - 12
SICI:
0168-9002(1995)360:1-2<7:DOLHTD>2.0.ZU;2-O
Fonte:
ISI
Lingua:
ENG
Soggetto:
FIBERS;
Tipo documento:
Article
Natura:
Periodico
Settore Disciplinare:
Science Citation Index Expanded
Science Citation Index Expanded
Science Citation Index Expanded
Science Citation Index Expanded
Citazioni:
20
Recensione:
Indirizzi per estratti:
Citazione:
S. Buontempo et al., "DEVELOPMENT OF LARGE-VOLUME, HIGH-RESOLUTION TRACKING DETECTORS BASEDON CAPILLARIES FILLED WITH LIQUID SCINTILLATOR", Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment, 360(1-2), 1995, pp. 7-12

Abstract

Searches for the decay of short-lived particles require real time, high-resolution tracking in active targets, which in the case of neutrino physics should be of large volume. The possibility of achieving thisby using glass capillaries filled with organic liquid scintillator isbeing investigated in the framework of the CHORUS experiment at CERN. In this paper, after outlining the application foreseen, advances in the tracking technique are discussed and results from tests are reported. An active target of dimensions 180 X 2 X 2 cm(3) has been assembled from capillaries with 20 mu m diameter pores. The readout scheme currently in operation allows the reading of similar to 5 x 10(5) channels using a single chain of image intensifiers having a resolution of sigma similar to 20 mu m Following the development of new liquid scintillators and purification methods an attenuation length of similar to 3 m has been obtained. This translates into a hit density of 3.5 per mm for a minimum-ionizing particle that crosses the active target at a distance of 1 m from the readout end.