TSE SEQUENCES WITH SELECTIVE SUPPRESSION COMPARED WITH CHEMICAL-SHIFTSEQUENCES IN MRI FOR DIFFERENTIATION AGAINST ADRENAL-TUMORS
Autore:
KREFT B; SOMMER T; VAHLENSIECK M; SEEWALD S; VETTER H; SCHILD H;
Indirizzi:
UNIV BONN,RADIOL KLIN,SIGMUND FREUD STR 25 D-53127 BONN GERMANY UNIV BONN,MED POLIKLIN D-53127 BONN GERMANY
Titolo Testata:
RoFo. Fortschritte auf dem Gebiete der Rontgenstrahlen und der neuenbildgebenden Verfahren
fascicolo: 4, volume: 162, anno: 1995,
pagine: 311 - 318
SICI:
0936-6652(1995)162:4<311:TSWSSC>2.0.ZU;2-9
Fonte:
ISI
Lingua:
GER
Soggetto:
COMPUTED-TOMOGRAPHY; MASSES; BIOPSY; GLAND; DISTINCTION; CARCINOMA; ADENOMAS; BENIGN; SIZE;
Keywords:
ADRENAL TUMOR; MAGNETIC RESONANCE IMAGING; CHEMICAL-SHIFT SEQUENCES; TURBO-SPIN-ECHO SEQUENCES; SELECTIVE FAT SUPPRESSION;
Tipo documento:
Article
Natura:
Periodico
Settore Disciplinare:
Science Citation Index Expanded
Citazioni:
28
Recensione:
Indirizzi per estratti:
Citazione:
B. Kreft et al., "TSE SEQUENCES WITH SELECTIVE SUPPRESSION COMPARED WITH CHEMICAL-SHIFTSEQUENCES IN MRI FOR DIFFERENTIATION AGAINST ADRENAL-TUMORS", RoFo. Fortschritte auf dem Gebiete der Rontgenstrahlen und der neuenbildgebenden Verfahren, 162(4), 1995, pp. 311-318

Abstract

Aim: The value of chemical-shift-gradient-echo sequences and turbo-spin-echo sequences with selective fat suppression (SPIR = Spectral Presaturation by Inversion Recovery) in the differentiation of benign and malignant adrenal tumours was investigated. Methods: Both techniques were performed at 1.5 T in 22 patients with 24 tumours. The loss of signal intensity of the tumour or of the signal intensity ratio between tumour and liver or muscle on the opposed phase Fast-Field-Echo (FFE) sequence in comparison to the in phase FFE sequence or on the TSE-SPIR sequence compared to the TSE sequence was the criterion for intratumoral lipid, suggesting a benign mass. Results: The sensitivity and specificity of the chemical shift technique was 62-77 and 100%, respectively. In adrenal tumours larger than 1.5 cm sensitivity of the chemical-shift technique was 89%. On the contrary sensitivity of the TSE-SPIR sequence was only 11-78%. Both techniques had a specificity of 100%. Conclusion: The chemical shift technique is more accurate in the differentiation of adrenal masses than the TSE-SPIR sequence.