EVALUATION OF CORRECTIVE RECONSTRUCTION METHODS USING A 3D CARDIAC-TORSO PHANTOM AND BULLS-EYE PLOTS
Autore:
ZHAO XD; TSUI BMW; GREGORIOU GK; LALUSH DS; LI J; EISNER RL;
Indirizzi:
UNIV N CAROLINA,DEPT BIOMED ENGN CHAPEL HILL NC 00000 UNIV N CAROLINA,DEPT RADIOL CHAPEL HILL NC 00000 EMORY UNIV,SCH MED,DEPT RADIOL ATLANTA GA 00000
Titolo Testata:
IEEE transactions on nuclear science
fascicolo: 6, volume: 41, anno: 1994,
parte:, 2
pagine: 2831 - 2837
SICI:
0018-9499(1994)41:6<2831:EOCRMU>2.0.ZU;2-J
Fonte:
ISI
Lingua:
ENG
Soggetto:
EMISSION COMPUTED-TOMOGRAPHY; ATTENUATION CORRECTION; ALGORITHMS; SPECT; EM;
Tipo documento:
Article
Natura:
Periodico
Settore Disciplinare:
Science Citation Index Expanded
Science Citation Index Expanded
Citazioni:
17
Recensione:
Indirizzi per estratti:
Citazione:
X.D. Zhao et al., "EVALUATION OF CORRECTIVE RECONSTRUCTION METHODS USING A 3D CARDIAC-TORSO PHANTOM AND BULLS-EYE PLOTS", IEEE transactions on nuclear science, 41(6), 1994, pp. 2831-2837

Abstract

The goal of our investigation was to study the effectiveness of the corrective reconstruction methods in cardiac SPECT using a realistic phantom and to qualitatively and quantitatively evaluate the reconstructed images using bull's-eye plots. A 3D mathematical phantom which realistically models the anatomical structures of the cardiac-torso regionof patients was used. The phantom allows simulation of both the attenuation distribution and the uptake of radiopharmaceuticals in different organs. Also, the phantom can be easily modified to simulate different genders and variations in patient anatomy. Two-dimensional projection data were generated from the phantom and included the effects of attenuation and detector response blurring. The reconstruction methods used in the study included the conventional filtered backprojection (FBP) with no attenuation compensation, and the first-order Chang algorithm, an iterative filtered backprojection algorithm (IFBP), the weighted least square conjugate gradient algorithm and the ML-EM algorithm with non-uniform attenuation compensation. The transaxial reconstructed images were rearranged into short-axis slices from which bull's-eye plots of the count density distribution in the myocardium were generated. The FBP reconstructed images clearly demonstrated the effects of attenuation on the myocardial distribution caused by anatomical structures and the inadequacy of the algorithm to provide accurate quantitativereconstructions. The images reconstructed using the Chang, IFBP, and ML-EM methods with attenuation compensation showed substantial improvement in terms of reduction in artifacts and improvement in quantitative accuracy. The results also demonstrate that the ML-EM method is the most robust in attenuation compensation for a wide range of anatomicalvariations when compared to the Chang and IFBP methods. The combination of the 3D mathematical phantoms and bull's-eye plots provides an effective tool for evaluation of corrective reconstruction methods for quantitative cardiac SPECT.