Catalogo Articoli (Spogli Riviste)

OPAC HELP

Titolo:
ASSESSMENT OF DNA OXIDATIVE DAMAGE BY QUANTIFICATION OF THYMIDINE GLYCOL RESIDUES USING GAS-CHROMATOGRAPHY ELECTRON-CAPTURE NEGATIVE IONIZATION MASS-SPECTROMETRY
Autore:
NARITSIN DB; MARKEY SP;
Indirizzi:
NIMH,CLIN SCI LAB,ANALYT BIOCHEM SECT,BLDG 10,ROOM 3D40 BETHESDA MD 20892 NIMH,CLIN SCI LAB,ANALYT BIOCHEM SECT BETHESDA MD 20892
Titolo Testata:
Analytical biochemistry
fascicolo: 1, volume: 241, anno: 1996,
pagine: 35 - 41
SICI:
0003-2697(1996)241:1<35:AODODB>2.0.ZU;2-4
Fonte:
ISI
Lingua:
ENG
Soggetto:
THYMINE GLYCOL; CHEMICAL-IONIZATION; QUANTITATIVE-DETERMINATION; RAT URINE; BASE; ACID; IDENTIFICATION; METABOLITES; TRYPTOPHAN; ADDUCTS;
Tipo documento:
Article
Natura:
Periodico
Settore Disciplinare:
Science Citation Index Expanded
Citazioni:
36
Recensione:
Indirizzi per estratti:
Citazione:
D.B. Naritsin e S.P. Markey, "ASSESSMENT OF DNA OXIDATIVE DAMAGE BY QUANTIFICATION OF THYMIDINE GLYCOL RESIDUES USING GAS-CHROMATOGRAPHY ELECTRON-CAPTURE NEGATIVE IONIZATION MASS-SPECTROMETRY", Analytical biochemistry, 241(1), 1996, pp. 35-41

Abstract

A technique to assess DNA oxidative damage by quantification of thymidine glycol residues is described. 2-Methylglycerate was released fromthymidine glycol in DNA by alkaline cleavage/borodeuteride reduction,then derivatized to form a combined pentafluorobenzyl-tertbutyldimethylsilyl (PFB-TBDMS) derivative and analyzed by gas chromatography/electron capture negative ionization mass spectrometry. [H-2(4)]Thymine glycol was used as an internal standard. The derivatization chemistry was assessed by using [C-14-methyl]glycerate. Successful esterification was achieved with 75-80% yield using tetrabutylammonium sulfate-assisted anhydrous pentafluorobenzylation. The PFB-TBDMS derivative exhibitsexcellent chromatographic and detection properties with a detection limit of 41 amol injected on column. Freshly dissolved calf thymus DNA was used to test the method performance. The background level of thymidine glycol detected in this DNA was 11.7 +/- 0.3 x 10(-6) mol thymidine glycol per 1 mol thymidine. The thymidine glycol background in undamaged DNA establishes a lower limit of oxidative damage below which biological oxidation events would not be measured by this method. The method was linear for 4-20 mu g DNA added per tube. The minimum measurable amount of thymidine glycol in DNA sample was 36 fmol. An increased level of thymidine glycol was measured in salmon sperm DNA which had autoxidized during storage in a refrigerated aqueous solution, 71.2 +/-14.3 x 10(-6) mol thymidine glycol per 1 mol thymidine. (C) 1996 Academic Press, Inc.

ASDD Area Sistemi Dipartimentali e Documentali, Università di Bologna, Catalogo delle riviste ed altri periodici
Documento generato il 09/07/20 alle ore 22:32:03