DETERMINATION OF RESPIRATORY RATE ON THE BASIS OF RESPIRATORY SINUS ARRHYTHMIA
Autore:
BETTERMANN H; ENGELKE P; VANLEEUWEN P; HECKMANN C;
Indirizzi:
GEMEINSCHAFTSKRANKENHAUS HERDECKE,ABT KLIN FORSCH D-58313 HARDECKE GERMANY GEMEINSCHAFTSKRANKENHAUS HERDECKE,ABT KLIN FORSCH D-58313 HARDECKE GERMANY EFMT BOCHUM GERMANY
Titolo Testata:
Biomedizinische Technik
fascicolo: 11, volume: 41, anno: 1996,
pagine: 319 - 323
SICI:
0013-5585(1996)41:11<319:DORROT>2.0.ZU;2-B
Fonte:
ISI
Lingua:
GER
Keywords:
RESPIRATORY RATE; RESPIRATORY SINUS ARRHYTHMIA; 24-HOUR (HOLTER) ECG;
Tipo documento:
Article
Natura:
Periodico
Settore Disciplinare:
Science Citation Index Expanded
Science Citation Index Expanded
Citazioni:
10
Recensione:
Indirizzi per estratti:
Citazione:
H. Bettermann et al., "DETERMINATION OF RESPIRATORY RATE ON THE BASIS OF RESPIRATORY SINUS ARRHYTHMIA", Biomedizinische Technik, 41(11), 1996, pp. 319-323

Abstract

In the clinical setting, the observation of undisturbed spontaneous respiration and direct measurement of an ''unbiased'' respiratory rate is not a practical option. However, the respiratory modulation of the heart rate (respiratory sinus arrhythmia, RSA) offers a possibility ofrecording the respiratory rate indirectly. The present work introduces a novel procedure for extracting the respiratory rate from the ECG, and compares the results thus obtained with those of a previously applied method. The latter is based on the determination of dominant peaksin the amplitude spectrum of a five-minute RR interval time series. The new method presented here is based on the band pass filtering of a one-minute RR interval time series with subsequent analysis of the maxima, minima and zero crossings of the resulting RSA curve. The methodswere compared by determining the respiratory rates of 16 healthy malesubjects measured in 15 different experimental situations, including spontaneous and controlled breathing, The respiratory rate as determined by thermistor recording of nasal breath temperature was used as control. The mean deviation from directly measured respiratory rate was 2.9 min(-1) for the new and 7.2 min(-1) for the previous method. The new method proved superior under all conditions except controlled breathing at low frequencies. The present study thus demonstrates the high precision of respiratory rate determined indirectly by analysing the RSA curve. Since it requires no special instrumentation, this procedure is ideally suited for clinical application, and permits the continuousrecording of respiratory rate over long periods of time.