POWER VERSUS CONVENTIONAL COLOR DOPPLER SONOGRAPHY - COMPARISON IN THE DEPICTION OF VASCULATURE IN LIVER-TUMORS
Autore:
CHOI BI; KIM TK; HAN JK; CHUNG JW; PARK JH; HAN MC;
Indirizzi:
SEOUL NATL UNIV HOSP,COLL MED,DEPT RADIOL,CHONGNO GU,28 YONGON DONG SEOUL 110744 SOUTH KOREA
Titolo Testata:
Radiology
fascicolo: 1, volume: 200, anno: 1996,
pagine: 55 - 58
SICI:
0033-8419(1996)200:1<55:PVCCDS>2.0.ZU;2-W
Fonte:
ISI
Lingua:
ENG
Soggetto:
HEPATOCELLULAR-CARCINOMA; PULSED DOPPLER; ULTRASOUND; DIAGNOSIS; US;
Keywords:
LIVER NEOPLASMS, BLOOD SUPPLY; LIVER NEOPLASMS, US; ULTRASOUND (US), COMPARATIVE STUDIES; ULTRASOUND (US), DOPPLER STUDIES;
Tipo documento:
Article
Natura:
Periodico
Settore Disciplinare:
Science Citation Index Expanded
Citazioni:
14
Recensione:
Indirizzi per estratti:
Citazione:
B.I. Choi et al., "POWER VERSUS CONVENTIONAL COLOR DOPPLER SONOGRAPHY - COMPARISON IN THE DEPICTION OF VASCULATURE IN LIVER-TUMORS", Radiology, 200(1), 1996, pp. 55-58

Abstract

PURPOSE: To compare power and conventional color Doppler sonography in the depiction of the intratumoral vasculature of hemangiomas, hepatocellular carcinomas (HCCs), and metastases of the liver. MATERIALS ANDMETHODS: Thirty-two patients with liver tumors (12 hemangiomas, 11 HCCs, and nine metastases) were prospectively evaluated with power and conventional color Doppler sonography by using a 2-4-MHz convex probe with 2-MHz Doppler frequency. Power Doppler sonography was performed with a 75%-88% gain Conventional color Doppler sonography was performed with a 55%-75% gain and a pulse repetition frequency of 700 Hz. Power Doppler signals and color Doppler signals interrogated in one plane were analyzed by two radiologists, who subjectively rated power Doppler sonography as superior, equal, or inferior to color Doppler sonography. RESULTS: Overall, power Doppler sonography was superior to color Doppler sonography in 18 patients and equal in 14 (P < .01). In hemangiomas, power Doppler sonography was superior to color Doppler sonography in 10 patients and equal in two (P < .01). In HCCs, power Doppler sonography was superior to color Doppler sonography in four patients and equal in seven (P > .05). In metastases, power Doppler sonography was superior to color Doppler sonography in four patients and equal in five(P < .05). CONCLUSION: Power Doppler sonography is more sensitive than color Doppler sonography in the depiction of the vasculature of Liver tumors, particularly in hemangiomas.