SYSTEMIC FILLING PRESSURE IN THE INTACT CIRCULATION DETERMINED WITH ASLOW INFLATION PROCEDURE
Autore:
DENHARTOG EA; JANSEN JRC; MOENS GH; VERSPRILLE A;
Indirizzi:
ERASMUS UNIV ROTTERDAM,DEPT PULM DIS,PATHOPHYSIOL LAB,POB 1738 NL-3000 DR ROTTERDAM NETHERLANDS ERASMUS UNIV ROTTERDAM,DEPT PULM DIS,PATHOPHYSIOL LAB NL-3000 DR ROTTERDAM NETHERLANDS
Titolo Testata:
Pflugers Archiv
fascicolo: 6, volume: 431, anno: 1996,
pagine: 863 - 867
SICI:
0031-6768(1996)431:6<863:SFPITI>2.0.ZU;2-4
Fonte:
ISI
Lingua:
ENG
Soggetto:
VENOUS RETURN;
Keywords:
VENOUS RETURN; CENTRAL VENOUS PRESSURE; INSPIRATORY PAUSE PROCEDURES; VENOUS CAPACITY; VENOUS RESISTANCE; MECHANICAL VENTILATION;
Tipo documento:
Article
Natura:
Periodico
Settore Disciplinare:
Science Citation Index Expanded
Citazioni:
10
Recensione:
Indirizzi per estratti:
Citazione:
E.A. Denhartog et al., "SYSTEMIC FILLING PRESSURE IN THE INTACT CIRCULATION DETERMINED WITH ASLOW INFLATION PROCEDURE", Pflugers Archiv, 431(6), 1996, pp. 863-867

Abstract

In eight mechanically ventilated, anaesthetized pigs weighing 10.3 +/- 0.8 kg(mean +/- SD) we studied the effect of the inflation time of the lung on the estimation of the mean systemic filling pressure (P-sf)from the changes in venous return and central venous pressure during inflation of the lung. For this purpose we applied slow inflation procedures (SIP) to the lung with inflation times of 2.4, 4.8, 7.2, 9.6 and 12 s at tidal volumes (V-T) Of 15 and 30 ml/kg. The data were compared with the values of P-sf Obtained from inspiratory pause procedures (IPPs). A linear regression between venous return and central venous pressure applied during a SIP underestimated P-sf compared with the value obtained with IPPs. An exponential fit through the values of P-sf obtained from the different SIPs predicted an inflation time of about 15 s for an estimation of P-sf that is not different from the P-sf (IPP). The advantage of the SIP method is that the P-sf can be determined much faster than with the method based on IPPs. However, due to the rather long inflation time needed, the method may be only applicable under circumstances where neurohumoral control mechanisms are suppressed as during intensive care and anaesthesia.