Catalogo Articoli (Spogli Riviste)

OPAC HELP

Titolo:
REVIEW OF THE DEVELOPMENT OF CESIUM IODIDE PHOTOCATHODES FOR APPLICATION TO LARGE RICH DETECTORS
Autore:
ALMEIDA J; AMADON A; BESSON P; BOURGEOIS P; BRAEM A; BRESKIN A; BUZULUTSKOV A; CHECHIK R; COLUZZA C; DIMAURO A; FRIESE J; HOMOLKA J; IACOVELLA F; LJUBICIC A; MARGARITONDO G; MINE P; NAPPI E; DELLORTO T; PAIC G; PIUZ F; POSA F; SANTIARD JC; SARTORI P; SGOBBA S; VASILEIADIS G; WILLIAMS TD;
Indirizzi:
CERN CH-1211 GENEVA SWITZERLAND CERN CH-1211 GENEVA SWITZERLAND ECOLE POLYTECH FED LAUSANNE LAUSANNE SWITZERLAND CENS,DAPNIA GIF SUR YVETTE FRANCE WEIZMANN INST SCI IL-76100 REHOVOT ISRAEL IST NAZL FIS NUCL I-70126 BARI ITALY POLITECN BARI BARI ITALY TECH UNIV MUNICH W-8046 GARCHING GERMANY IST NAZL FIS NUCL PADUA ITALY UNIV PADUA PADUA ITALY RUDJER BOSKOVIC INST ZAGREB CROATIA ECOLE POLYTECH,LPNHE,CNRS,IN2P3 PALAISEAU FRANCE SUBATECH NANTES FRANCE
Titolo Testata:
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment
fascicolo: 1-3, volume: 367, anno: 1995,
pagine: 332 - 336
SICI:
0168-9002(1995)367:1-3<332:ROTDOC>2.0.ZU;2-7
Fonte:
ISI
Lingua:
ENG
Soggetto:
PRESSURE WIRE CHAMBER;
Tipo documento:
Article
Natura:
Periodico
Settore Disciplinare:
Science Citation Index Expanded
Science Citation Index Expanded
Science Citation Index Expanded
Science Citation Index Expanded
Citazioni:
18
Recensione:
Indirizzi per estratti:
Citazione:
J. Almeida et al., "REVIEW OF THE DEVELOPMENT OF CESIUM IODIDE PHOTOCATHODES FOR APPLICATION TO LARGE RICH DETECTORS", Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment, 367(1-3), 1995, pp. 332-336

Abstract

CsI photocathodes were studied in order to evaluate their potential use as large photoconverters in RICH detectors for the PID system at ALICE (LHC in heavy ion collider mode). It has been demonstrated that a quantum efficiency comparable to the reference value obtained on smallsamples can be obtained on CsI layers evaporated on large pad electrodes operated in a MWPC at atmospheric pressure. We present a survey ofthe results obtained in the laboratory on small samples irradiated with UV-monochromatic beams and with RICH detectors of proximity-focusing geometry at a 3 GeV/c pion beam.

ASDD Area Sistemi Dipartimentali e Documentali, Università di Bologna, Catalogo delle riviste ed altri periodici
Documento generato il 28/11/20 alle ore 09:54:29